dc.descriptionTo study fatigue of defective welds, beam-column joints were cyclically loaded at MWD Central Laboratories. However, local buckling occurred in the beam
flanges during the first few cycles at displacement ductilities 2.25-2.6. Despite the buckling, the peak resisted load had a maximum of 15% reduction after 10 cycles at these ductilities, and the hysteresis loops showed little change
in shape. Nevertheless, because steel frame structures can be expected to sustain a ductility demand of about 4/SM or 6, there is clearly some doubt as to whether the strength of a system already buckling at a DF < 3 would be maintained under
the design earthquake. The 310 UB 40 beam tested complied with the current NZ Steel Code, which required no stiffeners in this case.en-US
dc.formatapplication/pdf
dc.languageeng
dc.publisherNew Zealand Society for Earthquake Engineeringen-US
dc.relationhttps://bulletin.nzsee.org.nz/index.php/bnzsee/article/view/963/939
dc.rightsCopyright (c) 1982 S. J. Thurstonen-US
dc.rightshttps://creativecommons.org/licenses/by/4.0en-US
dc.sourceBulletin of the New Zealand Society for Earthquake Engineering; Vol 15 No 2 (1982); 96en-US
dc.source2324-1543
dc.source1174-9857
dc.titleLocal buckling of universal beam flangesen-US
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeTechnical Noteen-US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record